FEATURES

  • Digital tempreture setting and display.
  • Modular: units may be added in parallel at a later date.
  • Titanium pool heat exchanger.
  • Trouble free and sealed.
  • Ultra quiet - low noise fan availability (7-20dbA lower).
  • Soundproofed compressor.
  • Weatherproof: satin finished stainless steel (304) thourghout.
  • 25% less running time than comparative units -TK models.
  • Auto corrosion: pool water diverted from unit when not running - TK models.
  • Auto pump saver: pool filtration pump only activated when pool requires heating (optinal extra).
  • Auto display: LED's show low water flow, HP trip, defrost and pool temperature.
  • Auto installs - no adjustments or settings required for installation.
  • Automatic defrost - TK models auto-defrost down to +2C ambient.

    OTHER SPECIFICATIONS

  • Low Ambient: Low ambient temerature Cut-out on HP models. Defrost on TK units.
  • Pool Condenser: Titanium inside PVC tube.
  • Performance: Based on 25C ambient web bulb and 15C pool water.
  • Pool Temp: Nominal 15 - 35C range.
  • Plumbing connections: 50mm PVC.
  • Fan unit: Horizontal discharge. Vertical discharge optional.
  • Compressor: Bristol (USA) compressor.
  • Safetly Controls: HP, LP, low ambient, low water flow, compressor delayed start.
  • Refrigerant: R22.

    Performance & Dimentions

    MODEL Voltage Running
    Current
    Supply
    MCB
    Power
    Input
    Heat
    Output
    Water
    Flow 1/m
    P
    kPa
    Height
    mm
    Width
    mm
    Length
    mm
    Weight
    Kg
    HP range is for extended summer heating only
    HP10 220 - 240 7.4A 15A 1.7kW 10kW 120 30 640 535 890 75
    HP12 220 - 240 10.0A 15A 2.0kW 12kW 120 30 640 535 890 75
    HP15 220 - 240 12.5A 25A 2.5kW 15kW 120 30 640 535 890 75
    HP18 220 - 240 14.5A 25A 3.0kW 18kW 120 30 640 775 1220 96
    HP20 220 - 240 16.5A 30A 3.6kW 20kW 120 30 640 775 1220 98
    HP20 380 - 420 5.5A 15A 3.6kW 20kW 120 30 640 775 1220 101
    HP25 380 - 420 7.2A 15A 4.3kW 25kW 120 30 640 775 1220 103
    HP30 380 - 420 8.0A 15A 5.1kW 30kW 180 30 870 775 1220 124
    HP35 380 - 420 9.0A 20A 5.9kW 35kW 180 30 870 775 1220 125
    HP40 380 - 420 9.7A 20A 6.7kW 40kW 180 30 870 775 1220 127
    HP45 380 - 420 10.5A 30A 7.4kW 45kW 180 30 1180 1160 1220 158
    HP50 380 - 420 13.6A 30A 9.0kW 50kW 180 30 1180 1160 1220 166
    HP60 380 - 420 16.3A 35A 10kW 60kW 300 30 1180 1160 1220 167
    HP70 380 - 420 19.5A 35A 11.7kW 70kW 300 30 1180 1160 1220 173
     
    *TK range - professional choice for summer and winter heating
    TK10 220 - 240 7.4A 15A 1.7kW 10kW 120 60 640 535 890 75
    TK12 220 - 240 10.0A 15A 2.0kW 12kW 120 60 640 535 890 75
    TK15 220 - 240 12.5A 25A 2.5kW 15kW 120 60 640 775 1220 96
    TK18 220 - 240 14.5A 25A 3.0kW 18kW 120 60 640 775 1220 98
    TK20 220 - 240 16.5A 30A 3.6kW 20kW 120 60 640 775 1220 103
    TK20 380 - 420 5.5A 15A 3.6kW 20kW 120 60 640 775 1220 103
    TK25 380 - 420 7.2A 15A 4.3kW 25kW 120 60 870 775 1220 124
    TK30 380 - 420 8.0A 15A 5.1kW 30kW 180 60 870 775 1220 125
    TK35 380 - 420 9.0A 20A 5.9kW 35kW 180 60 870 775 1220 127
    TK40 380 - 420 9.7A 20A 6.7kW 40kW 180 60 1180 1160 1220 160
    TK45 380 - 420 10.5A 30A 7.4kW 45kW 180 60 1180 1160 1220 164
    TK50 380 - 420 13.6A 30A 9.0kW 50kW 180 60 1180 1160 1220 166
    TK60 380 - 420 16.3A 35A 10kW 60kW 300 60 1180 1160 1220 167
    TK70 380 - 420 19.0A 35A 11.7kW 70kW 300 60 1180 1160 1220 173
    *TK requires 25% less running in summer and bypasses pool water when not running.

    The System and how it works

      

    The HYDROPOOL is a refrigerator in reverse. It removes energy from the air and transfers it to your pool water. Running cost savings are typically 80% of conventional methods.

     

    Installation

    No fuss, no adjustments, trouble free - the unit can be installed within an hour.

    Connect the electrics to the external connection box provided. See also the owner's manual.

    We manufacture a large range of heat pumps. Most of our clients are universities, hospitals, hotels, local authorities and schools.

      

     

    Performance & Selection

    Pool heat losses are a function of pool surface area, pool over usage, wind velocity, pool temperature, air temperature and sun exposure - in that order. Consult your agent for the correct selection

    Connect the electrics to the external connection box provided. See also the owner's manual.

    We manufacture a large range of heat pumps. Most of our clients are universities, hospitals, hotels, local authorities and schools.

    Manufacturer reserves the right to change specifications without prior notification

    WARRANTY

    Tekniheat warrants this equipment to be free from defects in material and workmanship for a period of 12 months from plant commissioning or 15 months from date of shipment, whichever is the shorter period. Any units or parts proving defective within this period will be repaired or replaced at our option when returned to our factory transportation charges pre-paid. TEKNIHEAT will not be responsible for any installation or removal costs.